HIOKI 3198 MANUAL PDF

View and Download Hioki PW manual online. Power quality analyzer. PW Measuring Instruments pdf manual download. HIOKI PW is certified Class A and delivers Class A performance. Useful functions of the HIOKI PW (Manually customize settings afterwards.).

Author: Grogul Arak
Country: Colombia
Language: English (Spanish)
Genre: Science
Published (Last): 18 October 2013
Pages: 232
PDF File Size: 13.60 Mb
ePub File Size: 11.58 Mb
ISBN: 130-3-37453-172-5
Downloads: 92439
Price: Free* [*Free Regsitration Required]
Uploader: Aragar

The PW is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues.

An optional current sensor is necessary to measure current or power parameters. You may be unable to read from or save data to such cards.

POWER QUALITY ANALYZER

TIME PLOT Data The PW can simultaneously record 8, or more parameters, such as voltage, current, power, power factor, frequency, integral power, harmonic, and flicker, at the specified recording interval. Voltage can be measured with the main unit alone. By offering over main products characterized by safety and quality while meeting an expansive range of applications, we aim to contribute to the efficiency and value of our customers’ work in research and development, production and electrical maintenance.

More accurate analysis of issue causes thanks to the ability to record 11 seconds surrounding anomalous events In the event of an instantaneous power outage or a swell, in yioki the voltage rises abnormally, the PQ hiokk record waveforms for 1 second before and 10 seconds after the anomaly.

By using a power quality analyzer, technicians can accurately and efficiently identify the causes of these issues. Flicker and V10 Recording. Removable SD Card Current sensors are necessary to measure current or power parameters sold seperately.

The quickest way to approach these problems is to understand the situation quickly and accurately. The number of power and energy problems is increasing as power systems are becoming more and more complicated – all due to the rising use of power electronics devices plus a growing installed base of large systems and distributed power supplies. Others No results were found. In this manuap, the application makes it easier to discover anomalies that occur during specific times of day or on specific days hooki the week.

  CANON POWERSHOT SD990 IS MANUAL PDF

Technical Notes No results were found. This capability manuap the need to provide a separate AC adapter or battery for each sensor, simplifying wiring in the vicinity of the instrument and enabling long-term measurement. NEW Data Sheet 4. The Hioki PW is a power quality analyzer for monitoring, recording and analyzing power quality parameters.

PW Our Model No: Gallery No results were found. By using this function, customers can reliably connect and configure the instrument, a majual which if not completed properly can lead to measurement errors.

Hioki Launches Power Quality Analyzer PQ – Hioki

As a result of these and related factors, the need to monitor power quality is growing. Issues such as voltage drops, flicker, harmonics etc. In this way, the instrument can accommodate a diverse range of customer measurement needs. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor negative-phase, zero-phase The PW never fails to capture the peak because it hloki calculations continuously and records the maximum, minimum, and average values within the recording interval.

Harmonic voltage-current phase angle: Compatibility and performance are not guaranteed for SD cards made by other manufacturers. Voltage can be measured with the main unit alone. Voltage swell, Voltage dips, Voltage interruption 5. Overview Specifications Downloads Options Applications Gallery Hioki portable power meters and analyzers are best in manuall power measuring instruments for measuring single to three-phase gioki with a high degree of precision and accuracy.

Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. Consequently, power issues are an everyday occurrence. Calculated as one bioki, 40 to 70 Hz 3. An optional current sensor is necessary to measure current or power parameters. Seminar Schedule No results were found. Currently, engineers use power quality analyzers to monitor and analyze power quality as they investigate the causes of electronic device malfunctions and failures triggered by power quality issues.

  GIULIANO SANTORO UN GRILLO QUALUNQUE PDF

Event List This list records instantaneous waveforms of power quality measurement failures eventssuch as a voltage drop or inrush current, along with the time or other information.

Against this backdrop, renewable energy sources such as solar power and wind power have been entering into increasingly widespread use.

K Factor multiplication factor Log into your myHioki account to access more technical documents and information where available. Detailed knowledge of the factors that cause such issues is necessary in order to combat them effectively, but such assessment is an extremely time-consuming task due to the large number of parameters that must be investigated and the advanced level of expertise required in order to do so.

Whereas the legacy Hioki PQA PW only records these pre- and post-event waveforms for 1 second, the new PQA lets engineers analyze the causes of anomalies using waveforms captured over a longer period of time. Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz HIOKI products and services are available around the world through our extensive network maunal subsidiaries and distributors.

Hioki PW3198 Manual

Event Waveform The PW lets you view the instantaneous waveform ms of a power supply failure in 33198 window. High level of basic measurement accuracy and extremely accurate voltage measurement without the need to switch ranges.

Easy to Set up – Just select the measurement course and the PW will do the rest Simply choose the course based on the measurement objective and the necessary configurations will be set automatically. View Cart My Account You can depend on the PW to monitor all aspects of your power supplies. As per IEC 8. Why Power Quality Measurement?